Types of Firestop Systems Used in Saudi Arabia | Passive Fire Protection Solutions
- murtaza
- November 9, 2025
- Uncategorized
- 0 Comments
In Saudi Arabia’s rapidly developing construction landscape, firestop systems are among the most essential components of passive fire protection. Whether in Riyadh’s commercial towers, Dammam’s industrial facilities, or Jeddah’s high-rise developments, the correct selection and installation of firestop systems ensure compliance with Saudi Civil Defense regulations and international safety standards. These systems work silently yet powerfully to contain fire, smoke, and heat—protecting both lives and property.
This comprehensive guide explores the main types of firestop systems used in Saudi Arabia, their technical features, and the critical reasons why engaging certified fire protection contractors is a necessity for every modern project.
In This Article:
1. Penetration Firestop Systems
Penetration firestop systems are designed to seal openings created when pipes, conduits, or cables pass through fire-rated walls and floors. Without proper sealing, these openings can allow smoke and flames to spread rapidly.
- Typical Locations: Electrical rooms, mechanical shafts, risers, and service cores.
- Common Products: Intumescent sealants, firestop collars, putty pads, and mortar systems.
- Performance: Tested for up to 4-hour fire ratings under UL or ASTM standards.
2. Joint Firestop Systems
Expansion and construction joints move over time due to structural loads, thermal changes, or seismic activity. Joint firestop systems are engineered to accommodate this movement while maintaining the required fire barrier integrity.
| Joint Type | Description | Typical Firestop Material |
|---|---|---|
| Wall-to-Wall Joints | Seals between vertical partitions. | Flexible fire-resistant sealant and mineral wool backing. |
| Floor-to-Wall Joints | Located at the junction between slabs and walls. | Firestop spray coating over mineral wool and joint backing. |
| Slab Edge Joints | Critical for high-rise façades and curtain wall assemblies. | Perimeter fire barrier systems using safing insulation and sealant. |
3. Perimeter Curtain Wall Firestop Systems
In high-rise construction, the space between the floor slab and the exterior curtain wall must be sealed using a perimeter fire containment system. This prevents vertical fire spread between floors, a key concern for Saudi Arabia’s commercial and mixed-use towers.
- Components: Safing insulation, fire-resistant sealants, and mechanical retainers.
- Applications: Aluminum and glass façades, spandrel panels, and high-rise towers in Riyadh and Jeddah.
- Regulatory Compliance: Must comply with SBC 801 and ASTM E2307 standards.
4. Mechanical and Electrical Firestopping
Mechanical and electrical rooms typically contain multiple penetrations for HVAC ducts, cable trays, and conduit bundles. Firestopping these areas is essential to maintaining the compartmentation strategy of the building.
Advanced materials such as intumescent wraps, fire-rated pillows, and modular firestop sleeves are often used to achieve re-entry capability for future maintenance—an important consideration for large infrastructure projects in KSA.
5. Firestop Materials and Components
Each firestop system is only as effective as the materials and methods used. High-quality, third-party tested materials are essential for long-term performance. Common categories include:
- Sealants: Acrylic, silicone, and intumescent sealants designed for specific substrates.
- Mortars and Putties: Used for larger openings and complex penetrations.
- Wrap Strips and Collars: Expand during fire exposure to seal plastic pipe openings.
- Firestop Boards: Rigid or semi-rigid boards for mechanical enclosures and shafts.
“Effective firestopping is not just a product—it’s a tested system. Always select assemblies that have documented fire resistance ratings and installation certifications.”
6. Saudi Civil Defense Compliance and Testing
All firestop systems used in Saudi Arabia must comply with local codes enforced by Saudi Civil Defense and align with international standards such as UL 1479 (for penetrations) and ASTM E1966 (for joints). Inspections typically require photographic evidence, product data sheets, and certification records from approved manufacturers like Hilti, 3M, and Tremco.
Firestop contractors are expected to maintain quality assurance documentation for each installed system, ensuring the building passes the official safety inspections and occupancy approval process.
Conclusion: Building with Fire Integrity
Modern architecture in Saudi Arabia demands more than aesthetic appeal—it requires resilient safety systems integrated from the earliest design stage. Selecting the correct firestop system and partnering with an experienced fire protection contractor ensures that your building is fully protected, code-compliant, and ready for the challenges of the future.
Need expert consultation for certified firestop systems in Riyadh, Jeddah, or Dammam?